Performance Should Be Proven.

Pure Way systems are developed using professionally selected filtration technologies and components evaluated against recognized drinking water industry standards.

As part of our commitment to engineering transparency, Pure Way maintains membership with the Water Quality Association (WQA), utilizes certified system components where applicable, and pursues independent third-party laboratory performance evaluation.

This approach allows performance data to be measured objectively, not assumed.

INDUSTRY MEMBERSHIP

Pure Way maintains membership within the water treatment industry’s leading professional association focused on education, standards, and responsible water quality practices.

CERTIFIED COMPONENTS

Select components are certified by IAPMO R&T to recognized NSF/ANSI drinking water standards, including 42, 61, and 37.  For more information, visit https://pld.iapmo.org.

INDEPENDENT LAB TESTING

System peformance evaluationwas condctd unde conolled laboraoy conditions to measure reduction performance across multiple contaminant categories.

Verified Performance

Laboratory Testing Results

TESTED UNDER AGGRESSIVE CHALLENGE CONDITIONS

Our goal in pursuing independent laboratory evaluation was simple: provide measureable performance data developed under controlled laboratory conditions using intentionally concentrated challenge water.

Testing utilized elevated influent concentrations across multiple contaminant categories, including microbiological organisms, chemical compounds, and millions of microplastic particulates per milliliter to evaluate system performance under aggressive laboratory challenge conditions.

Laboratory: BCS Laboratories

ISO17025 Methodology

Elevated Challenge Water

BCS Reports: 2603149-3152

CONTAMINANT

VERIFIED REDUCTION

PFAS (Forever Chemicals) Compounds Evaluated
PFOA • PFOS • PFHxS • PFBS • PFDA
> 99.3%
TTHMs (Total Trihalomethanes) >99.93%
VOCs (Volatile Organic Compounds) >99.94%
Microplastics >99.9%
 Chlorine >99.1%
 Chloramine >99.6%
 Lead (Pb) >99.92%
 HAA5 (Haloacetic Acids) >98.7%
HAA9 (Haloacetic Acids >98.7%
 Virus / MS-2 Bacteriophage >99.9998%
Bacteria / R. terrigena >99.9999%
Cysts / Cryptosporidium >99.997%
Pharmaceuticals >99.3%

 

Independent laboratory evaluations was conducted by BCS Laboratories an ISO/IEC 17025:2017 accredited analytical laboratory under controlled analytical conditions.  Actual performance may vary based on source water quality, installation conditions, flow rate, and system maintenance.